Cl. Venturitubes acc. EN ISO 5167



Application

For flow measurements with high demand for accuracy, short upstream- and downstream

conditions and low pressure drop. Application in power plants for steam and feed water measurements, also as billing measurements for the complete industrial sector.


Pros

•  Accuracy ±0,7% to ±3% according to operating data

•  Great long-term accuracy

•  No maintenance cost

•  Low pressure drop, about 10-15% from the calculated differential pressure

•  Short up- and downstream sections required

 

Specification

Nominal diameter from DN50 - DN1200

Pressure rating from PN6 – PN600

Other dimensions, temperature and pressure ratings also possible on request.

 

Assembly

Venturi tubes could be mounted in each position.

 

Materials

Venturitubes in EN, ASTM and ASME materials like

f. e. 1.4571, 1.0460, 1.5415, 1.7335, 1.7380, 1.6368, 1.4903, 1.4901. Other materials by request.


KERN Technology GmbH & Co. KG  +++  Römerstraße 11  +++  D-67304 Eisenberg  +++  Tel. (+49) 6351 – 49062-0  +++  Fax (+49) 6351 – 49062-22